Revco Elite Chest / Upright Freezers

from Thermo Fisher Scientific

Revco* Elite Chest & Upright Freezers from Thermo Fisher ScientificULT1050-5-A ULT1050-5-D ULT1050-5-V ULT1050-5-W ULT1090-5-A ULT1090-5-D ULT1090-5-V ULT1090-5-W ULT1340-5-A ULT1340-5-D ULT1340-5-V ULT1340-5-W ULT1386-5-A ULT1386-5-D ULT1386-5-V ULT1386-5-W ULT1450-5-A ULT1450-5-D ULT1450-5-V ULT1450-5-W ULT1490-5-A ULT1490-5-D ULT1490-5-V ULT1490-5-W ULT1740-5-A ULT1740-5-D ULT1740-5-V ULT1740-5-W ULT1750-5-A ULT1750-5-D ULT1750-5-V ULT1750-5-W ULT1790-5-A ULT1790-5-D ULT1790-5-V ULT1790-5-W ULT2050-5-A ULT2050-5-D ULT2050-5-V ULT2050-5-W ULT2090-5-A ULT2090-5-D ULT2090-5-V ULT2090-5-W ULT2140-5-A ULT2140-5-D ULT2140-5-V ULT2140-5-W ULT2540-5-A ULT2540-5-D ULT2540-5-V ULT2540-5-W ULT350-5-A ULT350-5-D ULT350-5-V ULT350-5-W ULT390-5-A ULT390-5-D ULT390-5-V ULT390-5-W ULT750-5-A ULT750-5-D ULT750-5-V ULT750-5-W ULT790-5-A ULT790-5-D ULT790-5-V ULT790-5-W

Discontinued

Our Revco Elite freezers are built to meet high standards for performance and safety.

  • They feature microprocessor controls, alarm/monitor systems and rugged cabinet construction found throughout our entire freezer product line.
  • Maximize the value of your freezer with our intelligent rack solutions and accessories.

Control System.

  • Microprocessor control system with touchpad data entry and digital display of all functions.
  • Key-operated switch for main power and alarm.
  • Independent operating temperature and high/low limit alarm functions with factory-set defaults for quick start-up, all setpoints adjustable in 1°C increments.

Electrical System.

  • On-board power monitoring with digital readout of incoming line voltage.
  • Optional free-standing surge suppressor minimizes effect of voltage spikes from incoming electrical service.

Operating Temperature.

  • Chest or Upright Freezer (CUF1): -10°C to -40°C.
  • Chest or Upright Freezer (CUF2): -50°C to -86°C.

Alarm System.

  • A.I.M. (Automatic Incident Monitor) identifies any temperature deviation beyond alarm setpoints, with rapid flash for current event, slow flash if event was self-corrected; A.I.M. archives most deviated temperature.
  • Adjustable safety alarm with automatic, continuous charge battery backup provides full alarm function in case of power failure.
  • Power failure or temperature deviation triggers audible and visual warning.
  • Digital battery indicator displays battery capacity; flashing low battery indicator advises when to replace battery.
  • Touchpad alarm test function physically warms internal probe to simulate alarm condition.
  • RS-232 data port with system software package.
  • Exterior alarm contacts for connection to remote monitoring system.

Monitoring System.

  • Voltage boost indicator advises of low source voltage below safe parameters and indicates voltage boost system is activated.
  • Clean filter indicator light advises when to remove and wash condenser filter.

PRODUCT TECHNICAL DATA SHEET