Revco Ultima II Chest / Upright Freezers

from Thermo Fisher Scientific

Revco* Ultima II Chest & Upright Freezers from Thermo Fisher ScientificULT1050-9-A ULT1050-9-D ULT1050-9-V ULT1050-9-W ULT1090-9-A ULT1090-9-D ULT1090-9-V ULT1090-9-W ULT1340-9-A ULT1340-9-D ULT1340-9-V ULT1340-9-W ULT1386-9-A ULT1386-9-D ULT1386-9-V ULT1386-9-W ULT1450-9-A ULT1450-9-D ULT1450-9-V ULT1450-9-W ULT1490-9-A ULT1490-9-D ULT1490-9-V ULT1490-9-W ULT1740-9-A ULT1740-9-D ULT1740-9-V ULT1740-9-W ULT1750-9-A ULT1750-9-D ULT1750-9-V ULT1750-9-W ULT1790-9-A ULT1790-9-D ULT1790-9-V ULT1790-9-W ULT2050-9-A ULT2050-9-D ULT2050-9-V ULT2050-9-W ULT2090-9-A ULT2090-9-D ULT2090-9-V ULT2090-9-W ULT2140-9-A ULT2140-9-D ULT2140-9-V ULT2140-9-W ULT2540-9-A ULT2540-9-D ULT2540-9-V ULT2540-9-W ULT350-9-A ULT350-9-D ULT350-9-V ULT350-9-W ULT390-9-A ULT390-9-D ULT390-9-V ULT390-9-W ULT750-9-A ULT750-9-D ULT750-9-V ULT750-9-W ULT790-9-A ULT790-9-D ULT790-9-V ULT790-9-W

Discontinued

Developed for the most critical material storage.

Ultra-Low and Cryogenic Storage.

  • Available in general purpose and blood bank configurations, each of our Revco Ultima II freezers include the IntrLogic microprocessor control system with built-in voltage boost and surge suppressor.
  • Models feature convenient eye-level controls on upright models, and comprehensive monitoring technology such as Lifeguard compressor protection, A.I.M. incident monitor, and extreme ambient alert.

Operating Temperature.

  • Chest Freezer (CF): -40°C to -86°C.
  • Upright Freezer (UF): -50°C to -86°C.
  • Chest or Upright Freezer (CUF): -10°C to -40°C.

Control System.

  • Exclusive IntrLogic microprocessor control system with touchpad data entry and digital display of all functions.
  • Setpoint security system with key-operated switch for main power and alarm locks in temperature and alarm setpoints.
  • On-board power monitoring with digital readout of incoming line voltage.
  • Built-in surge suppressor minimizes effect of voltage spikes from incoming electrical service.

Alarm System.

  • A.I.M. (Automatic Incident Monitor) identifies any temperature deviation beyond alarm setpoints, with rapid flash for current event, slow flash if event was self-corrected; A.I.M. archives most deviated temperature.
  • Adjustable safety alarm with automatic, continuous charge battery backup provides full alarm function in case of power failure.
  • Power failure or temperature deviation triggers audible and visual warning.
  • Digital battery indicator displays battery capacity; flashing low battery indicator advises when to replace battery.
  • Touchpad alarm test function physically warms internal probe to simulate alarm condition.
  • RS-232 data port with system software package.
  • Exterior alarm contacts for connection to remote monitoring system.

Monitoring System.

  • Lifeguard compressor protection monitors performance and automatically adjusts to internal and external conditions, extending compressor life.
  • Extreme ambient alert warns if room temperature may affect performance.
  • Voltage boost indicator advises of low source voltage below safe parameters and indicates voltage boost system is activated.
  • Surge suppressor indicator advises to check intercept fuse.
  • Clean filter indicator light advises when to remove and wash condenser filter.

PRODUCT TECHNICAL DATA SHEET