BriskHeat Kits / Accessories

from BriskHeat Corp

BriskHeat* Kits & Accessories AAT2180 AAT260 BCLCAB JBM001 JBM002 JHE-GET JHS-GET JHT-GET PSAT36A PTBO-GET ROOFCLIP25 ROOFDOWN3 ROOFEND5 ROOFPKIT RTV3.0 SLCABEND-CSA-2 SLCABKC SLCABSK SLCABUC SLCABUC-CSA-M SLCBL-RCLIP10 SLCBL-RCLIP50 SLCBL-RDOWN1 SLCBLKC SLCBLSK SLCBLUC SLCBLUC-GF SLMCABKC

Approvals valid only when used with appropriate heating cable and installation accessories, and installed in accordance with all applicable instructions, codes, and regulations.

AAT260 | AAT2108 | PSAT36A : Adhesive Tape.

  • Helps to isolate the cable from the insulation and provides intimate contact with surface to be heated.
  • BCLCAB: Caution Label.

  • Required by code for every 10ft (3m) of pipe.
  • JBM001 | JBM002 : Junction Box.

  • Metallic Junction Box with 1” (25mm) NPT thread. Includes watertight cover and 3/4” (19mm) NPT adaptor.
  • Suitable for use in ordinary, wet locations with gasket when cover is closed. NEMA FB-1.
  • Listed File No. E3397 (UL 514A Standard).
  • CertifiedFile No. LR11852 (CSA C22.2 No. 18 Standard).
  • Hazardous-Area Rated Junction Box available upon request.
  • JHE-GET: CSA End Seal Kit.

  • (1) End seal housing.
  • (1) Watertight sealing grommet.
  • (1) Pressure seal end with screws.
  • JHS-GET: CSA Low-Profile Inline Splice Connection Kit.

  • (1) In-line splice housing.
  • (2) Watertight sealing gaskets.
  • (2) Housing covers with screws.
  • (2) Watertight sealing grommets.
  • (2) Pressure seal ends with screws.
  • JHT-GET: CSA Low-Profile Tee Splice Kit.

  • (1) Tee splice housing.
  • (2) Watertight sealing gaskets.
  • (2) Housing covers with screws.
  • (3) Watertight sealing grommets.
  • (3) Pressure seal ends with screws.
  • PTBO-GET: CSA Octagon Junction Box Power Connection Kit.

  • Provides input power connection for SLCBL, SLMCBL, and SLHCBL self-regulating heating cable.
  • Enough to complete one input power connection or one input power splice connection.
  • For use in hazardous area locations with SLCBL cable only (CSA approved).
  • For use in non-hazardous area locations with SLCBL, SLMCBL, SLHCBL cable (non-CSA approved).
  • ROOFCLIP25: Roof Clips for SLCAB.

  • (25) Roof Clips.
  • ROOFDOWN3: Downspout Hanger Kit for SLCAB.

  • (3) Downspout hangers.
  • ROOFEND5: SLCAB Roof and Gutter End Seal Kit.

  • (5) Black Shrink Tubes, 0.5” (13mm) diameter, 4” (102mm) length.
  • (5) Black Shrink Tubes, 0.5” (13mm) diameter,1.5” (38mm) length.
  • ROOFPKIT: SLCAB Roof and Gutter Power Connection Kit.

  • (1) Ground screw.
  • (1) Grommet.
  • (1) Sealing fitting:connector body, cap, gland washer, and locknut.
  • (3) Shrink sleeve, 0.5” (13mm) diameter, 1.5” (38mm) length.
  • (1) Yellow / green shrink sleeve.
  • (2) Shrink sleeve 0.125” (3mm) diameter, 5.5” (140mm) length.
  • (3) Crimp connectors.
  • (2) Shrink sleeve, 0.75” (19mm) diameter, 6” (152mm) length.
  • (1) Ring terminal.
  • NOTE: Includes a weatherproof junction box.
  • RTV3.0: RTV Sealant.

  • Silicone sealant used to seal lead pouches, end pouches, and pipe standoffs.
  • SLCABEND-CSA-2: SLCAB and SLMCAB End Seal Kit. CSA approved.

  • (1) End cap.
  • (1) Clamp.
  • (1) Sealant.
  • SLCABKC: SLCAB End Seal Kit. FM approved.

  • (10) Heat shrink tubes.
  • SLCABSK: SLCABSK Kit. FM approved.

  • (20) Large yellow crimp connectors.
  • (20) Large blue crimp connectors.
  • (10) Heat shrink tubes.
  • (1) 3 oz. (89ml) tube of RTV sealant.
  • SLCABUC: SLCAB Universal Connection Kit. FM approved.

  • (1) 3/4” (19mm) NPT pipe standoff.
  • (2) Ring terminals.
  • (4) Large, insulated crimp connectors.
  • (2) Small, insulated crimp connectors.
  • (2) Pipe straps (for up to a 6” [152mm] IPS pipe).
  • (2) Heat shrink end caps.
  • (1) 6” (152mm) shrink sleeve.
  • (1) 3 oz. (89ml) tube of RTV sealant.
  • (1) Roll of fiberglasstape.
  • (1) Caution label.
  • (1) Ground screw.
  • NOTE: Requires a 3/4” (19mm) NPT junction box.
  • SLCABUC-CSA-M: SLCAB and SLMCAB Universal Connection Kit. CSA approved.

  • (1) Connector body.
  • (1) Connector cap.
  • (2) Connector gland washers.
  • (1) Grommet.
  • (1) Termination boot.
  • (1) Strain relief grip.
  • (1) Standoff bracket.
  • (1) Locknut.
  • (1) Termination block.
  • (1) Roll of fiberglasstape.
  • (1) Silicone sealant.
  • (1) Pipe strap (for 2” to 6” [51 to 152mm] O.D. pipes).
  • (1) Ring tongue terminal.
  • (1) End seal kit.
  • NOTE: Requires a 3/4” (19mm) NPT junction box.
  • SLCBLKC: End Seal Kit.

  • (2) Heat-shrink caps.
  • (2) Heat-shrink tubes 3/4”x 5”(19mm x 13cm).
  • (2) Woven braid sleeves 1/2”x 4”(13mm x 10cm) .
  • SLCBL-RCLIP10 | SLCBL-RCLIP150 : SLCBL Roof & Gutter Clips.

  • Used to safely position and secure heating cable to shingle and metal seam roofs as part of a roof & gutter snow melting and de-icing system.
  • For use with SLCBL and SpeedTrace self-regulating heating cable for roof & gutter snow melting and de-icing.
  • SLCBL-RDOWN1: SLCBL Downspout Hanger Kit.

  • Used to safely position heating cable into downspouts as part of a roof & gutter snow melting and de-icing system.
  • Provides mechanical protection to prevent damage to the heating cable as it may go over sharp edges in roof & gutters.
  • For use with SLCBL and SpeedTrace self-regulating heating cable for roof & gutter snow melting and de-icing.
  • Must be bent at 90° and secured with UV resistant cable ties before installation.
  • SLCBLSK: Splice Connection Kit.

  • (1) Clamp tie.
  • (3) Cable ties.
  • (1) Cloth tape.
  • (5) Mastic strips.
  • (2) Heat-shrink caps.
  • (1) Black heat-shrink tube 1”x 8”(25mm x 20cm).
  • (3) Black heat-shrink tubes 1/2”x 1”(13mm x 25mm).
  • (6) Black heat-shrink tubes 1/8”x 1”(3mm x 25mm).
  • (1) Heat-shrink tube.
  • (2) Crimp-on insulated terminals.
  • (1) Crimp-on non-insulated barrel.
  • (1) End seal.
  • SLCBLUC: Power Connection Kit.

  • (2) Heat-trace warning labels.
  • (2) De-icing snow melt caution labels.
  • (1) Standoff pipe mounting bracket.
  • (1) Pipe Strap.
  • (1) Lock nut.
  • (1) Sealing gasket.
  • (1) 1/2”NPT Seal fitting.
  • (3) Wire nuts.
  • (1) Black heat-shrink tube 1/2”x 1”(13mm x 25mm).
  • (1) Green/Yellow heat-shrink tube 1/4”x 6”(6mm x 15cm).
  • (2) Black heat-shrink tubes 1/8”x 5-1/2”(3mm x 14cm).
  • (1) End seal.
  • SLCBLUC-GF: Power Connection With Ground Fault Kit.

  • (2) Heat-trace warning labels.
  • (2) De-icing snow melt caution labels.
  • (1) Cloth tape.
  • (2) Mastic strips.
  • (2) Clamp ties.
  • (2) Crimp-on insulated terminals.
  • (1) Crimp-on non-insulated barrel.
  • (1) Heat-shrink tube 3/4”x 8”(19mm x 20cm).
  • (1) Heat-shrink tube 3/4”x 5”(19mm x 13cm).
  • (2) Heat-shrink tubes 1/8”x 1”(3mm x 25mm).
  • (1) Heat-shrink tube 1/2”x 1”(13mm x 25mm).
  • (1) Heat-shrink tube 5/16”x 1-1/2”(8mm x 38mm).
  • (1) Ground fault device with 120V 3-Prong NEMA 5-15 plug.
  • SLMCABKC: SLMCAB End Seal Kit. FM approved.

  • (10) End boots.
  • (4) Rolls of fiberglasstape.
  • (1) 3 oz. (89ml) tube of RTV sealant.
  • SLMCABUC: SLMCAB Universal Connection Kit. FM approved.

  • (1) 3/4” (19mm) NPT pipe standoff.
  • (2) Ring terminals.
  • (3) Large, crimp connectors.
  • (2) Small, crimp connectors.
  • (2) Pipe straps (for up to a 6” [152mm] IPS pipe).
  • (2) End boots.
  • (1) 3 oz. (89ml) tube of RTV sealant.
  • (1) Roll of fiberglasstape.
  • (1) Caution label.
  • (1) Ground screw.
  • NOTE: Requires a 3/4” (19mm) NPT junction box.
  • PRODUCT TECHNICAL DATA SHEET